888 7 ASSAYS (888-727-7297)
 
     
Caspase / Apoptosis Detection
High Throughput Screening
- Apo3HTS
Caspase Poly,1,2,3,7,8,9,10 Detection - FAM-FMK
Caspase Poly, 1,2,3,8,9,10, Detection
- (SR-FMK)
Antibody Specific Caspase 3 Detection
- Apo Active 3 (FITC)
Antibody Specific Caspase 3 Detection
- Apo Active 3 (PE)
NOS/ROS Detection Kits
Nitric Oxide Synthase Detection Kit - NOS New!!!
Hydroxyl (OH)/ Peroxynitrite (ONOO-)Detection Kit - Fluoro Hydroxyl / Peroxynitrite New!!!
Hypochlorite (Ocl-) Detection Kit
- Fluoro Hypochlorite New!!!
Fluorescent Enzymatic Assays
Catalase Detection Kit
- Fluoro Catalase
Monoamine oxidase A&B detection - Fluoro MAO
Semicarbazide sensitive amine oxidase detection
- Fluoro SSAO
Hydrogen Peroxide detection - Fluoro H202
Mitochondria Membrane Potential detection
Mitochondria Membrane Potential - JC 1
MM Potential detection
for Flow Cytometry

- Mito Flo
aCella - Bioluminescence Assays Kits
Non Radioactive Assay for Cytotoxicity - aCella TOX
Monitoring Acetylcholinesterase activity - aCella AChE New!!!
Cytotoxicity
Antibody Mediated Cytotoxicity - ACT 1
ELISA Products
Conjugate Diluents
Assay Diluents
Sample Diluents
Wash Buffers
Plate Coating Buffers
Block Buffers
Cathepsin B,K,L Detection Kits
Substrate based Assay to detect protease activity in hole living cells
   

 

 
 
5x Universal Plate Coating Buffer
Improves Assays:
  • Saves valuable reagents. By promoting a higher specific signal, less protein may be needed to coat the plate and less of the detection molecules may be needed to generate a signal when this buffer is used.
  • Increases the shelf-life of your plates. Depending on the activity of the coated protein, plates may be stored at room temperature or 2°-8°C for several months, or even years under proper conditions.
  • Increases reproducibility. By using consistent reagents from a reliable source, your ELISAs may become more reproducible.
  • Increases the signal of the ELISA. If the antibody or antigen is not sticking to the plate, or unwanted proteins are interfering with binding, the plate will have an overall low specific signal. CB1 may foster adsorption and reduce interference.
  • Decreases background noise. If excess proteins are sticking to the plate, plate will have overall high backgrounds (a high signal overall, but a low specific signal). Universal Plate Coating Buffer may reduce interference.
How it Works:
Our Coating Buffer is an optimal formulation of buffers and salts which maximizes the adsorption of antibodies and antigens onto polystyrene plates. During the adsorption process, the Coating Buffer stabilizes coated proteins by maintaining their tertiary three-dimensional structure. By stabilizing the adsorbed protein, antigenic regions are preserved, allowing for greater binding reactivity with the detection molecule, thereby enhancing the specific signal. By generating a higher specific signal, a lower concentration of coat protein may be needed when this buffer is used, thereby saving valuable reagents.
Directions:
Simply dilute Coating Buffer 1:5 (for example, add 100mL Coating Buffer to 400mL diH20 for a final volume of 500mL) , add your protein antigen or antibody, let the solution stir for 15 minutes, and pipette onto the plate.
ECB100 Universal Plate Coating Buffer
Cell Technology has specifically formulated a unique plate coating buffer for use with antibodies and antigens. The pH and ionic strength of this buffer have been specifically formulated to create an optimal coating environment which maximizes the adsorption efficiency of most antibodies and protein antigens onto polystyrene plate surfaces. This buffer also stabilizes coated proteins, preserving antigenic regions, and allowing for greater binding reactivity with the detection molecule, enhancing the specific signal. By generating a higher specific signal, a lower concentration of coat protein may be needed when this buffer is used, thereby saving valuable reagents.
5x Universal Plate Coating Buffer (ECB100)
5x Bottle Size
Price per Bottle
Part Number
Volume at 1x #Plates at 50uL/well
(4.8mL/plate)
#Plates at 200uL/well
(9.6mL/plate)
#Plates at 300uL/well
(28.8mL/plate)
100 mL
$40 644
500mL
100
25
16
500 mL
$95 645
2.5L
510 125 84
1 L $195.00 646
5L 1020
250 170
10 L $1350.00 658 50L 10,200
2,500 1,700
* Please call 888 7 ASSAYS (888-727-7297) or email info@celltechnology.com for volume pricing